| OPERATION MODE |
Independent |
Two independent outputs and 5V fixed
output |
| Output from 0 to rating volts and 0 to
rating amperes |
| Series |
Output from 0 to ± rating volts at rating amperes each |
| Output from 0 to double rating volts at
rating amperes |
| Parallel |
Output from 0 to double rating amperes at
rating volts |
| CONSTANT VOLTAGE OPERATION |
Regulation |
Line regulation < 0.01% + 3mV |
| Load regulation < 0.01% + 3mV (rating current < 3A) |
| Load regulation < 0.02% + 5mV (rating current <
10A) |
| Ripple & Noise |
< 1mVrms 5Hz ~ 1MHz |
| Recovery Time |
< 100µ s (50% Load change, Minimum load 0.5A) |
| CONSTANT CURRENT OPERATION |
Regulation |
Line regulation < 0.2% + 3mA |
| Load regulation < 0.2% + 3mA |
| Ripple & Noise |
< 3mArms |
| TRACKING OPERATION |
Tracking Error |
< 0.5% + 10mV of the
master |
| Series Regulation |
< 300mV |
| METER |
Digital |
Accuracy ±
(0.5% of rdg + 2 digits) |
| 5V FIXED OUTPUT |
Regulation |
Line regulation < 5mV |
| Load regulation < 10mV |
| Ripple & Noise |
< 2mVrms |
| Voltage Accuracy |
5V ±
0.25V |
| Output Current |
3A |
| INSULATION |
Chassis and Terminal |
20MW or above (DC 500V) |
| Chassis and AC Cord |
30MW or above (DC 500V) |
| POWER SOURCE |
AC 100V, 120V, 240V ±
10% 50/60Hz (External Switchable) |
| ACCESSORIES |
Test lead GTL-105 x 3 (< 3A) or GTL-104 x 3 (< 10A) |
| Instruction manual x 1 |
| DIMENSIONS |
255 (W) x 145 (H) x 355 (D) |